Equipment Description
It consists of power module, motion unit, switching unit, negative pressure system, heat dissipation system, fire protection system, etc. The device is adjustable in the direction of probe spacing, height and width dimensions. It has the function of cell position detection and protection. After the needle bed pressing, the cell voltage is tested and abnormal ones will be segregated, and all the cells are processed in series only when normal is displayed to ensure safety. And a full range of testing tools will be equipped.
Equipment Features
- Modular Design:Compatible with a variety of cells with different side electrode column, compatible range 400-1000
- Negative Pressure Formation:Step vacuum time and adjustable frequency, which can be cut off according to the formation step
- Energy Waving and Consumption Reduction:Battery in series to reduce wire length and line loss, and thus improve the efficiency of the whole equipment
- Efficient Commissioning:Compared with parallel power supply, the commissioning and maintenance workload is reduced by more than 50% and the operation is convenient
- Safety Protection:The whole machine implements safety interlock, and the protective door is equipped with a security lock
Equipment Parameters
Voltage Test Range |
charge 0~5V; Discharge 1.8~5V; Resolution 0.1mV |
Current Test Range |
120mA~120A; Resolution 0.1mA |
Current Accuracy |
±0.025%FS+±0.025%RD |
Storage Temperature Control |
±3℃ |
Overall Charge Efficiency |
≥82% |
Module Communication Mode |
CAN communication |